Radiofrequency Voltage Measurements: Extension of Primary Power Standard below 10 MHz,Used

Radiofrequency Voltage Measurements: Extension of Primary Power Standard below 10 MHz,Used

In Stock
SKU: DADAX3848432749
Brand: LAP Lambert Academic Publishing
Condition: New
Regular price$100.00
Quantity
Add to wishlist
Add to compare

Sold by Ergodebooks, an authorized reseller.

Returns accepted within 30 days | support@ergodebooks.com

Verified
Shipping Information
  • Free Standard Shipping — United States only
  • Processing Time: 1–3 business days
  • Estimated Delivery: 3–5 business days after dispatch
  • Double-boxed, fully insured & discreetly packaged
  • Tracking number sent via email once dispatched
  • Orders over $250 require signature upon delivery. Taxes calculated at checkout.
Returns & Refund

Returns accepted within 30 days of delivery.

Damaged or Defective Item

Free return shipping + replacement or full refund

Wrong Item Received

Free return shipping + replacement or full refund

Change of Mind

Return shipping at customer's expense · 25% restocking fee applies

All returns require a Return Authorization (RA) number before sending.

To initiate a return, contact us:

support@ergodebooks.com +1 (281) 738-1050
View Full Return & Refund Policy
Payment Option
Payment Methods

Help

If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, withing 24 hours on weekdays.

Customer service

All questions about your order, return and delivery must be sent to our customer service team by e-mail at yourstore@yourdomain.com

Sale & Press

If you are interested in selling our products, need more information about our brand or wish to make a collaboration, please contact us at press@yourdomain.com

In the alternate voltage field at INRiM, the italian NMI, the reference voltage standard under 1 MHz is maintained in terms of ACDC Transfer Difference. On the other hand, over 10 MHz, the meaningful quantity is the electrical power which is always definable: for this reason the reference standard is maintained through the microcalorimetric technique. However, a gap exists between 1 MHz and 10 MHz in which no reference standard is defined, at least at INRiM. In the past this situation was not a problem, but recently an increasing demand for calibration over 1 MHz in terms of voltage and under 10 MHz in terms of power required to fill the existing metrological gap. Since the microcalorimetric technique is not further downward extensible, due to the fact that all the technical solutions adopted are at the state of the art, an alternative way must be found to fill the gap. The proposal is to extend the voltage measurements above the limit of 1 MHz, technique already adopted in other metrological institutes, that is to extend the ACDC Transfer Difference Standard. On the other hand a new procedure will be proposed to derive power measurements from the same voltage setup.

⚠️ WARNING (California Proposition 65):

This product may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

For more information, please visit www.P65Warnings.ca.gov.

Recently Viewed